Methodology & sources

For each month, multiply DC nameplate capacity by user-entered average daily plane-of-array peak sun hours, the actual calendar-day count and one combined derate. Sum all twelve months. A leap year uses 366 days.

Monthly kWh = system kW DC × sun hours/day × days in month × (1 − combined losses ÷ 100).

Check the example

An illustrative 6 kW system with 4.5 sun hours every day and 20% combined losses gives 21.6 kWh per day, 648 kWh over 30 days and 7,884 kWh over a 365-day year. Actual monthly sun hours can be quite different.

Boundaries and rounding

The combined loss input must include all effects you intend to model, including inverter and temperature effects. This is not PVWatts and its default is not PVWatts’ separate 14% system-loss input. No location dataset or live weather is silently applied. It does not size wiring, guarantee production, estimate subsidies or quote installer costs.

Calculations retain full precision internally and format the displayed answer. Lender, installer or insurer rules may round differently. Invalid, missing or out-of-range inputs stop the result instead of producing a plausible answer.

Primary references

Sources explain the subject and its limitations. They do not endorse this tool. Worked scenarios and examples are original; default numbers are hypothetical.